Stage

Proscenium Height:      20'0"

Proscenium Width:     50'0"

Apron Width:       +12' Above (6' each side)

Is Apron Curved?     Yes - 12'-6" @ CL: 4' @ sides

Is Apron Moveable?     No

Offstage Left - Prosc. to offstage wall;   14'-6"

Restrictions?    Fly Rail @ 5' - 6; Fence @ 8' 7" rail is intermittent

Ceiling Height Off - Right:   32' - 0" - Loading rail 6' W x 24' L

Plaster Line to back wall:  28' - 0"

Describe access from House to Stage:   Steps SL & SR

Describe access from House to Backstage:   Hallway on left and right of house

Is the stage wheelchair accessible?    Yes, from backstage

Is the backstage wheelchair accessible?  Yes, same as above

How is security maintained?   Campus security/Alarm system

Can scenery/props be left onstage overnight?   Yes

Is there a fee for security?   No

Floor:

Type and condition:  soft wood T & G over concrete; good condition

Color of stage floor?   Ebony

Restrictions:   No paint, nails or screws

Describe type and condition of offstage floor:   Same as above, good condition

Stage Diagrams:

Plaster Line to Farthest upstage hanging position:  23' - 9"

Stage Measurements:

THERE ARE NO PROVISIONS FOR ANY ADDITIONAL STAGE MIKE INPUTS OR FOR ANY DIRECT LINE LEVEL INPUTS.

Line 1 - Valence - @ Plaster Line - 15’-6” from floor to bottom of drape

Line 2 - Grand Drape - 2’-0” from PL - dead hung travelling

Line 3 - First Electric - 3’-3” from PL - flying

Line 4 - Pipe - 5’-0” from PL - dead hung - 21’-10” from floor to pipe

Line 5 - Flying Baton - 5”-6” from PL

Line 6 - Second Electric - 8’-0” from PL - flying

Line 7 - Traveler - 8’-4” from PL - dead hung

Line 8 - Flying Baton - 10’-0” from PL

Line 9 - Pipe - 10’-6” from PL - dead hung - 15’-3” from floor to bottom of teaser (if used) - 22’-9” from     floor to pipe

Line 10 - Flying Baton - 12’6” from PL

Line 11 - Pipe - 13’-0” from PL- dead hung - 21’-9” from floor to pipe

Line 12 - Third Electric - 12’9” fro PL - flying

Line 13 - Pipe - 16’-0” from PL - dead hung - 21’-10” from floor to pipe

Line 14 - Flying Baton - 17’-8” from PL

Line 15 - Flying Baton - 19’-0” from PL

Line 16 - Pipe - 20’-0” from PL - dead hung - 15’-3” from floor to bottom of teaser     (if used) - 22’-9” from floor to pipe

Line 17 - Flying Baton - 20’-6” from PL

Line 18 - Fourth Electric - 21’-8” from PL - flying

Line 19 - Flying Baton - 23’-0” from PL

Line 20 - Traveler - 23’-6” from PL - dead hung

Line 21 - Cyc - 23’-9” from PL - flying

Stage Right Storage:

There is a 10’-0” deep area that runs the entire 28’-0” length of the stage. It is divided into three (3) areas.

1. 4’-0” out from the SR wall can be used for storage.
2. The next 4’-0” out is occupied by the fly system.
3. The next 2’-0” out can be used for offstage storage.

Stage Left Storage:

20’-0” back from the PL there is an 8’-0” x 10’-0” space at the rear of the stage that can be used for SL offstage storage. Other space is occupied by a piano and two drapery hampers.

There is a 4’-3” walkway between the rear wall of the theatre and the Cyc. This is used for crossover purposes during a show.

 


KENTUCKY COMMUNITY & TECHNICAL COLLEGE SYSTEM

T R A N S F O R M I N G   L I V E S.   T R A N S F O R M I N G   K E N T U C K Y