ELECTRICS

Tie-ins:

Company Box available?   Yes: Union Connector with 3 pole

Location of tie-in:   SR wall

Describe type of electrical service:   3 phase 4 wire. 400 amp service.  Cam-Lock J-Series receptacles.    (Outside electric company can be called for hook - up and on standby.)

Normal location of road dimmers:  SR by venue dimmers

Distance from tie-in to road dimmers:   Located next to each other

Distance from dimmers to house electric/audio position:    SR to rear of theatre in sound booth. (80+ Feet) SR to house audio positions: House Left-60+f House Right-80+ft.

House System:

Number of Dimmers:  128

Dimmer capacity:   2.4 KW

Type:    Strand CD-80SV

Number operational:   128

House Control:

Brand/Model:   Strand/LBX

Configuration:   96x1; 72x1 w/ 24 subs; 48x2; 36x2 with 24  subs

House operator required?    No

Location:   FOH

DMX remote locations:    Backstage right

Dimmers:

Type:    Strand CD-80SV

Number of amps per circuit:     20 amp limit

Location:   SR

Obstructions/Restrictions:    Behind fly rail

Other:   2 independent automatically selecting, AMX,DMX, and SMX input ports, and 32 pile-on; analog control channels. 

Lighting Positions:

FOH:

Cat Walk?   Yes

Number of circuits:   36

Distance to PL at center?    28’-0”

Cove?  None

How many?   None

Number of circuits per:    None

Box Booms?   None

How many?   None

Number of circuits per:    None

Permanent installations/focuses?    None

Describe any focus restrictions or obstructions that may be a hindrance: First 4’ of apron difficult to light.

Onstage:

Number of electrics:     4

Number of circuits/electrical:    1E - 24; 2E - 22; 3E - 22; 4E - 16

Distance of electrics form Plaster Line:   1E @ 3’ -3” from PL; 2E @ 8’- 0” 3E @ 14’ - 9”;
4E @ 21’ - 8” from PL

What electric is normally used to light the Cyc?   4

What type of instrument is usually used?    Scoops - 500W or 1K

Floor pockets?    Yes

How many?   8

Locations:   3 SR, 3 SL, 2 US

Number of circuits/pocket:    1per pocket

Drop boxes?    None

Restrictions/Other:     None

Instrument Inventory:

12 - 36 degree Source 4  750W

21 - 26 degree Source 4  750W

4 - 19 degree Source 4  750W

26 - 750 W 6x9 Ellips - Spots - 40*

16 - 1 KW 8 x 14 Ellips - Spots - 10*

38 - 750 W 6” Fresnels

8 - 500W 16” Altman Scoops

2 - 8" Kliegel Fresnels

6 x 9’s - 4 are Altman 1KL6 - 40’s : 4 are  1KL6 - 2040Z:18 are Major instruments - Altman
Color media available?    Yes

Describe type of connector used ( 2 p&G, edison, etc.):    20 amp Twist Lock(5L-20)

Follow Spots:

Number & Type:    2 -1 KW Altspots

Model:    1000Q

Location:      Booth

Restrictions?      Trained operator; limited space to operate spot.

Misc:

120v service outlets backstage?   Yes

Where:     Floor pockets and wall outlets

How many?   8

Amperage:     20 per outlet

220V service backstage?    No

House lights operator from:    FOH and backstage SR

House lights manual or automated?   Can be controlled both ways

Work light controls located:   FOH and backstage SR

Are there ladders?   Yes - 2-10 ft./ 1-8ft. & 1-6ft.

Personnel Lift available?    Genie Lift  (250 lb. cap.)

Note:    Control for lobby lights located in Box Office.

KENTUCKY COMMUNITY & TECHNICAL COLLEGE SYSTEM

T R A N S F O R M I N G   L I V E S.   T R A N S F O R M I N G   K E N T U C K Y